HYQVIA (SC)

IgG-hyaluronidase, Recombinant


Note: HYQVIA IS DIFFERENT THAN OTHER SC INFUSIONS. IT COMES WITH TWO COMPONENTS - HY AND IG.


Pharmacy specific orders / instructions always supersede the Agency guidance provided below. If in doubt, do not guess, call our office, or tag @TeamHelp-CareCoordination(Best Tag) and ask for Clinical Support.



ALWAYS make sure you have everything you need to complete infusion before you begin

ALWAYS confirm your medication dose against the medication label and orders

ALWAYS reach out to us first (not the Pharmacy) with any questions

NEVER tell a Pt you have not given a particular medication before

MIXING

NOTE: HYQVIA comes with a Hy component and an IG component. 

 DO NOT mix the Hy component with the IG component.  They are given separately.   

Hy is a tissue expander.  The IG must be started within 10 minutes of infusing the IG. 


  1. First prepare the Hy component of HyQvia

  2. Prepare the IG and have it ready to infuse

  3. See the attached for preparation either using the HyHub system or using a pooling bag Important Reminders re HyHub or HyHub Duo

    • HyHub/HyHub Duo: Available with four docks or two docks

    • Single use only: Use a new HyHub or HyHub Duo for every infusion, even if all docks were not used

    • HYQVIA only: Do not use HyHub or HyHub Duo with other medications

    • Do not use with a pooling bag.

    • Do not connect HyHub or HyHub Duo to a syringe driver infusion pump

    • Patients should receive instruction and training from a healthcare provider before using HyHub or HyHub Duo at home

    • Follow the prescribed maximum infusion volume per site and infusion rate

    • Always follow the complete manufacturer Instructions for Use and current HYQVIA Prescribing Information

    • Hyqvia Admin via HyHub or Pooling Bag

ADMINISTRATION

  1. Take baseline vital signs, and document basic assessment

  2. Choose your infusion sites, clean the sites and access the sites with the needles placing Tegaderm or tape over the needles  

  3. Attach your needle set with the Hy and check for any blood return

    • If no blood return, continue

    • If blood return, remove the needle and start with a new needle set. 

  4. Infuse the Hy

    • Slow IVP at a rate of 1 – 2 ml/minute. 

  5. When Hy has been infused, clamp it, remove the syringe, attach the IG set, unclamp, and start the IG infusion and complete

    • Must start IG infusion within 10 minutes of infusing the Hy

  6. Monitor patient for any adverse reactions

  7. Record vital sings at baseline, every 15 minutes for first hour and then hourly AND 5-10 minutes post infusion.

  8. Record lot number and expiration date for syringe

  9. When infusion completed, clamp tubing and then remove the tegaderm and remove needles

    • Place bandage at site if needed

  10. Clean and dispose of used supplies

.

ADDITIONAL INFO

HCP Website: Hyqvia-HCP; Hyqvia-HCP 

Prescribing Info: Hyqvia-PI 

Dosing-Administration: Hyqvia-Dosing-Admin; Hyqvia-Admin w Peristaltic Pump-HyHub 

Syringe Driver Guide: Hyqvia-Infusion Syringe Driver Pump Guide



 

 