top of page

OPDIVO (IV)

nivolumab

**ALWAYS establish patent IV access and flush PRIOR to mixing medication**


Pharmacy specific orders / instructions always supersede the Agency guidance provided below. If in doubt, do not guess, call our office, or tag @TeamHelp-CareCoordination(Best Tag) and ask for Clinical Support.


ALWAYS establish IV access prior to mixing any meds

ALWAYS make sure you have everything you need to complete infusion before you begin

ALWAYS confirm your medication dose against the medication label and orders

ALWAYS reach out to us first (not the Pharmacy) with any questions

NEVER tell a Pt you have not given a particular medication before

MIXING

  1. Obtain a clear/clean space to prepare the

  2. Be sure all the necessary supplies are available to complete infusion from beginning to end.  You will need:

    • Medication, 0.9% sodium chloride injection, USP or 5% dextrose injection, USP for dilution, empty bag, syringe and needle, IV start supplies, IV tubing with in-line filter (pore size of 0.2-1.2 mm), bandage, gauze, alcohol

  3. Withdraw the required volume of OPDIVO and transfer into an empty bag

  4. Dilute OPDIVO with diluent to prepare an infusion with a final concentration ranging from 1 mg/mL to 10 mg/mL. The total volume of infusion must not exceed 160 ml.

    • For adult/pediatric patients with body weight >_ 40 kg, do not exceed total volume of infusion of 160 ml

    • For adult/pediatrics patients with body weight <_ 40 kg, total volume of infusion must not exceed 4ml/kg of body weight

  5. Mix dilution solution by gentle inversion

    • Do not shake

  6. Discard partially used vials or empty vials of OPDIVO

ADMINISTRATION

  1. Take baseline vitals and document basic assessment

  2. Spike the bag with tubing

  3. Infuse over 30 minutes

  4. Monitor patient for any adverse reactions

  5. Record vital signs at baseline, every 15 minutes for the first hour, hourly and with each rate change, AND 5-10 minutes post infusion

  6. Record lot numbers and expiration dates for vials used

  7. Flush the entire IV line at end of infusion

  8. Disconnect patient, and remove IV

    1. Place pressure bandage at site

  9. Clean and dispose of used supplies

ADDITIONAL INFO

HCP Website:  Opdivo HCP  Prescribing Info:    Opdivo PI   

Administration Guide:   Opdivo Administration 

 

 

 

© 2018-2023 by Helms Home Care

 

300 N NC 16 Business Hwy

Denver NC 28037

704-802-9625 (P)

888-502-5390 (F)
service@helmshomecare.com

​

​

​

​

bottom of page